OLYMPIAN OD30
Diesel Generator Set

Key Specifications

Diesel Standby Rating

29.6 kW

Emissions

U.S. EPA Tier 4I (EPA 40 CFR Part 1039 Interim Tier 4)

Summary

The Olympian OD30 diesel generator set features the Cat® C2.2, in-line 4, 4-cycle diesel engine, 60 Hz frequency, and a 29.6 kW standby rating. Single or three-phase options available. It features multiple voltage options, over 1000 hour of continuous run time, GCCP 1.2 control panel, high efficiency alternator, and compact design. Designed to meet ISO 8528-5 transient response requirements.

29.6 kW Diesel Generator Set

Benefits

Over 1000 Hours of Continuous Run Time

High Efficiency Alternator

Compact Design

Enables improved packaging, resulting in the smallest genset footprint

Standard 5-Year Warranty for Standby Applications

Including parts and labor

Product Features

Cat C2.2 Engine

  • Reliable, rugged, durable design
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Alternator

  • Designed to match performance and output characteristics of Cat diesel engines
  • Industry leading mechanical and electrical design
  • High efficiency

GCCP 1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 104°F (40°C )

Technical Specifications

Generator Set Info
Name Olympian OD30 Diesel Generator Set
Description The Olympian OD30 diesel generator set delivers 29.6 kW standby power at 60 Hz.
Manufacturer Caterpillar
Model Number OD30
Frequency 60 Hz
Emissions Class U.S. EPA Tier 4I (EPA 40 CFR Part 1039 Interim Tier 4)
Voltage 120-600
Speed 1800 rpm
Diesel Rating 29.6 kW
Application Standby
Engine Specifications
Engine Model Cat® C2.2 In-line 4, 4-cycle diesel
Bore 84 mm (3.3 in)
Stroke 100 mm (3.93 in)
Displacement 2.2 L (134 in³)
Compression Ratio 23.3:1
Aspiration Turbocharged air-to-air charge cooling
Fuel System Electronically actuated mechanical cassette type
Generator Set Dimensions
Length 1581 mm
Width 970 mm
Height 1193 mm
Weight 612 kg

Downloads

Olympian OD30 product datasheet

FAQ

Which applications is the Olympian OD30 diesel generator set suitable for?

The Olympian OD30 diesel generator set is suitable for commercial, industrial, and infrastructure applications such as buildings and telecommunications. It delivers a standby rating of 29.6 kW and operates at 60 Hz. 

What benefits does the Olympian OD30 diesel generator set provide during a power outage?

The Olympian OD30 diesel generator set provides reliable backup power during a power outage, ensuring continuous operation for critical loads and over 1000 hours of continuous run time. 

What power output, voltage, and frequency options are available for the Olympian OD30 diesel generator set?

The Olympian OD30 diesel generator set delivers reliable electrical performance with voltage options from 208/120 V to 600/346 V and a frequency of 60 Hz. Its Cat C2.2 engine-based system supports consistent operation, compact installation, and over 1000 hour continuous run time. 

For which temperatures and environments is the Olympian OD30 diesel generator set suitable?

The Olympian OD30 diesel generator set is designed for operation in standard ambient conditions up to 40°C (104°F). Its cooling system supports stable performance in typical installation environments, while the compact footprint enables flexible integration in commercial, industrial, and infrastructure sites requiring reliable standby power with consistent operating capability.

How efficient is the Olympian OD30 diesel generator set?

The Olympian OD30 diesel generator set uses the Cat® C2.2, in-line 4, 4-cycle diesel engine for efficient, reliable performance. Its high-efficiency alternator and GCCP control system help optimize fuel use and load response. Fuel consumption with fan is 2.59 gal/hr (9.8 L/hr) at 100% load, 1.85 gal/hr (7 L/hr) at 75% load, and 1.35 gal/hr (5.1 L/hr) at 50% load.