OLYMPIAN OD100
Diesel Generator Set

Key Specifications

Diesel Standby Rating

100 kW

Emissions

U.S. EPA certified for stationary emergency, Tier 3

Summary

The Olympian OD100 diesel generator set delivers 100 kW at 60 Hz for standby power applications. Powered by the Cat® C4.4 In-line 4, 4-cycle diesel engine with common rail fuel injection and turbocharged aspiration. Single or three-phase options available. It operates at 208-600 voltage, is EPA Tier 3 certified, and reliability tested for 500 hours. Designed for up to 131°F (55°C) ambient conditions, it offers up to 12% installed space savings and NFPA 110 compliance for standby applications.

100 kW Diesel Generator Set

Benefits

Saves up to 12% Installed Space

Requires less space for installation; leaves more room for your on-going operations

Reliability tested for 500 Hours

Ensures you can count on emergency power when it is needed

Alternator Features Class H Insulation

Highest classification ensures alternator durability

Designed for Zero Downtime

Meets ISO 8528-5 transient response requirements

Standard 5-Year Warranty for Standby Applications

Including parts and labor

Product Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

M-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 131°F (55°C)

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Olympian dedicated product support, including service, parts, and warranty, covers the entire power system

Certifications

  • UL 2200
  • NFPA110

      Technical Specifications

      Generator Set Info
      Name Olympian OD100 Diesel Generator Set
      Description The Olympian OD100 diesel generator set delivers 100 kW at 60 Hz with a Cat® C4.4 In-line 4, 4-cycle diesel engine. EPA Tier 3 compliant, available in 208 V, 240 V, 480 V and 600 V configurations, and reliability tested for 500 hours.
      Manufacturer Caterpillar
      Model Number OD100
      Frequency 60 Hz
      Emissions Class EPA Tier 3
      Voltage 208-600
      Speed 1800 rpm
      Diesel Rating 100 kW
      Application Standby
      Engine Specifications
      Engine Model Cat® C4.4 In-line 4, 4-cycle diesel
      Bore 105 mm (4.1 in)
      Stroke 127 mm (5.0 in)
      Displacement 4.4 L (269 in³)
      Compression Ratio 16.7:1
      Aspiration Turbocharged
      Fuel System Common rail
      Generator Set Dimensions
      Length 2097 mm
      Width 1100 mm
      Height 1343 mm
      Weight 1008 kg

      Downloads

      Olympian OD100 product datasheet

      FAQ

      Which applications is the Olympian OD100 diesel generator set suitable for?

      The Olympian OD100 diesel generator set delivers 100 kW at 60 Hz and is designed for standby power applications. Complying with ISO 8528-5 transient response requirements, NFPA 110 loading requirements, and EPA Tier 3 emissions standards, it is well suited for facilities that require dependable emergency power and reliable electrical performance during utility power interruptions.

      What benefits does the Olympian OD100 diesel generator set provide during a power outage?

      The Olympian OD100 diesel generator set provides reliable standby power with 100 ekW at 60 Hz during utility power interruptions. Reliability tested for 500 hours, it is designed to ISO 8528-5 transient response requirements, accepts 100% block load in one step, and meets NFPA 110 loading requirements to support dependable emergency power when needed.

      What power output, voltage, and frequency options are available for the Olympian OD100 diesel generator set?

      The Olympian OD100 diesel generator set delivers 100 kW standby power at 60 Hz. It is available with voltage options of 208 V, 240 V, 480 V, and 600 V, providing flexible integration for a wide range of standby power requirements.

      For which temperatures and environments is the Olympian OD100 diesel generator set suitable?

      The Olympian OD100 diesel generator set is designed to operate in standard ambient temperatures up to 131°F (55°C). EPA Tier 3 compliant, ISO 8528-5 transient response performance, and UL 2200 certification, it is suited for installations requiring dependable standby power in demanding operating environments.

      How long can the Olympian OD100 diesel generator set run without interruption?

      The Olympian OD100 diesel generator set delivers 100 ekW at 60 Hz and is designed for standby operation during interruptions of utility power source. Reliability tested for 500 hours and engineered to ISO 8528-5 transient response requirements, it provides dependable standby power and consistent performance when emergency power is required.

      How efficient is the Olympian OD100 diesel generator set?

      The Olympian OD100 diesel generator set combines a Cat® C4.4 In-line 4, 4-cycle diesel engine with a Common Rail fuel injection system to deliver consistent performance and excellent fuel economy. Fuel consumption with fan is 7.4 gal/hr (27.9 L/hr) at 100% load, 5.9 gal/hr (22.5 L/hr) at 75% load, and 4.4 gal/hr (16.7 L/hr) at 50% load.